Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 21.397
1.
J Nanobiotechnology ; 22(1): 224, 2024 May 03.
Article En | MEDLINE | ID: mdl-38702709

Poorly identified tumor boundaries and nontargeted therapies lead to the high recurrence rates and poor quality of life of prostate cancer patients. Near-infrared-II (NIR-II) fluorescence imaging provides certain advantages, including high resolution and the sensitive detection of tumor boundaries. Herein, a cyanine agent (CY7-4) with significantly greater tumor affinity and blood circulation time than indocyanine green was screened. By binding albumin, the absorbance of CY7-4 in an aqueous solution showed no effects from aggregation, with a peak absorbance at 830 nm and a strong fluorescence emission tail beyond 1000 nm. Due to its extended circulation time (half-life of 2.5 h) and high affinity for tumor cells, this fluorophore was used for primary and metastatic tumor diagnosis and continuous monitoring. Moreover, a high tumor signal-to-noise ratio (up to ~ 10) and excellent preferential mitochondrial accumulation ensured the efficacy of this molecule for photothermal therapy. Therefore, we integrated NIR-II fluorescence-guided surgery and intraoperative photothermal therapy to overcome the shortcomings of a single treatment modality. A significant reduction in recurrence and an improved survival rate were observed, indicating that the concept of intraoperative combination therapy has potential for the precise clinical treatment of prostate cancer.


Carbocyanines , Mitochondria , Neoplasm Recurrence, Local , Photothermal Therapy , Prostatic Neoplasms , Male , Prostatic Neoplasms/diagnostic imaging , Photothermal Therapy/methods , Humans , Animals , Mitochondria/metabolism , Mitochondria/drug effects , Cell Line, Tumor , Carbocyanines/chemistry , Optical Imaging/methods , Mice , Surgery, Computer-Assisted/methods , Fluorescent Dyes/chemistry , Mice, Nude , Mice, Inbred BALB C , Infrared Rays , Indocyanine Green/chemistry , Indocyanine Green/therapeutic use , Indocyanine Green/pharmacology
3.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Article En | MEDLINE | ID: mdl-38717081

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Corneal Topography , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Refraction, Ocular , Surgery, Computer-Assisted , Visual Acuity , Humans , Keratomileusis, Laser In Situ/methods , Visual Acuity/physiology , Prospective Studies , Refraction, Ocular/physiology , Adult , Male , Female , Lasers, Excimer/therapeutic use , Double-Blind Method , Myopia/surgery , Myopia/physiopathology , Young Adult , Surgery, Computer-Assisted/methods , Middle Aged , Cornea/surgery , Cornea/physiopathology , Follow-Up Studies
4.
J Robot Surg ; 18(1): 209, 2024 May 10.
Article En | MEDLINE | ID: mdl-38727915

This study aimed to report our experience in indocyanine green (ICG) fluorescence-guided surgery (FGS) in pediatric robotics. The data of 55 patients (35 boys and 20 girls), who underwent robotic surgery using ICG fluorescence in three institutions over the last 7 years, were retrospectively reviewed. The following robotic procedures were included: pyeloplasty (n = 21), complex Lich-Gregoir ureteral reimplantation (n = 8), varicocelectomy (n = 7), adnexal pathology resection (n = 8), partial nephrectomy (n = 4), nephrectomy (n = 4), renal cyst removal (n = 2), and excision of prostatic utricle (n = 1). The ICG was injected intravenously in all indications except for varicocele where intratesticular injection was done, and prostatic utricle or paraureteral diverticulum where trans-catheter injection was done. The ICG dosage was 0.2-0.3 mg/mL/kg. All the procedures were performed using da Vinci Xi platform. Firefly® allowed to switch form bright light to ICG-NIRF view and vice versa. All the procedures were accomplished in robotics without conversions to laparoscopy or open surgery. No episodes of allergy or anaphylaxis to ICG were recorded. An excellent ICG-NIRF view of target organs was obtained in all procedures. Based on our experience, we believe that application of ICG FGS in pediatric robotics enhances the identification of critical anatomical elements and pathological structures, thereby positively impacting both oncological and functional outcomes. This technique is safe, feasible, and versatile. We advocate the consideration of ICG as the standard of care in certain procedures such as partial nephrectomy, varicocele repair, tumor resection, and ovarian torsion. Nonetheless, further investigations are warranted to explore its potential broader applications in pediatric urology.


Indocyanine Green , Robotic Surgical Procedures , Humans , Indocyanine Green/administration & dosage , Robotic Surgical Procedures/methods , Female , Male , Child , Retrospective Studies , Child, Preschool , Adolescent , Infant , Fluorescence , Nephrectomy/methods , Surgery, Computer-Assisted/methods
5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 179-183, 2024 Mar 30.
Article Zh | MEDLINE | ID: mdl-38605618

Objective: To introduce a locating device for the entry point of intramedullary nail based on the inertial navigation technology, which utilizes multi-dimensional angle information to assist in rapid and accurate positioning of the ideal direction of femoral anterograde intramedullary nails' entry point, and to verify its clinical value through clinical tests. Methods: After matching the locating module with the developing board, which are the two components of the locating device, they were placed on the skin surface of the proximal femur of the affected side. Anteroposterior fluoroscopy was performed. The developing angle corresponding to the ideal direction of entry point was selected based on the X-ray image, and then the yaw angle of the locating module was reset to zero. After resetting, the locating module was combined with the surgical instrument to guide the insertion angle of the guide wire. The ideal direction of entry point was accurately located based on the angle guidance. By setting up an experimental group and a control group for clinical surgical operations, the number of guide wire insertion times, surgical time, fluoroscopy frequency, and intraoperative blood loss with or without the locating device was recorded. Results: Compared to the control group, the experimental group showed significant improvement in the number of guide wire insertion times, surgical time, fluoroscopy frequency, and intraoperative blood loss, with a statistically significant difference (P<0.01). Conclusion: The locating device can assist doctors in quickly locating the entry point of intramedullary nail, effectively reducing the fluoroscopy frequency and surgical time by improving the success rate of the guide wire insertion with one shot, improving surgical efficiency, and possessing certain clinical value.


Fracture Fixation, Intramedullary , Surgery, Computer-Assisted , Humans , Bone Nails , Blood Loss, Surgical , Fluoroscopy/methods , Fracture Fixation, Intramedullary/methods , Surgery, Computer-Assisted/methods
6.
Med Image Anal ; 94: 103161, 2024 May.
Article En | MEDLINE | ID: mdl-38574543

Augmented Reality (AR) from preoperative data is a promising approach to improve intraoperative tumour localisation in Laparoscopic Liver Resection (LLR). Existing systems register the preoperative tumour model with the laparoscopic images and render it by direct camera projection, as if the organ were transparent. However, a simple geometric reasoning shows that this may induce serious surgeon misguidance. This is because the tools enter in a different keyhole than the laparoscope. As AR is particularly important for deep tumours, this problem potentially hinders the whole interest of AR guidance. A remedy to this issue is to project the tumour from its internal position to the liver surface towards the tool keyhole, and only then to the camera. This raises the problem of estimating the tool keyhole position in laparoscope coordinates. We propose a keyhole-aware pipeline which resolves the problem by using the observed tool to probe the keyhole position and by showing a keyhole-aware visualisation of the tumour. We assess the benefits of our pipeline quantitatively on a geometric in silico model and on a liver phantom model, as well as qualitatively on three patient data.


Augmented Reality , Laparoscopy , Neoplasms , Surgery, Computer-Assisted , Humans , Laparoscopy/methods , Computer Simulation , Liver , Surgery, Computer-Assisted/methods
7.
J Med Chem ; 67(7): 5800-5812, 2024 Apr 11.
Article En | MEDLINE | ID: mdl-38560986

Near-infrared (NIR) fluorescence imaging has attracted much attention in image-guided interventions with unique advantages. However, the clinical translation rate of fluorescence probes is extremely low, primarily due to weak lesion signal contrast and poor specificity. To address this dilemma, a series of small-molecule near-infrared fluorescence probes have been designed for tumor imaging. Among them, YQ-04-03 showed notable optical stability and remarkable sensitivity toward tumor targeting. Moreover, within a specific concentration and time range against oxidizing reducing agents and laser, it demonstrated better stability than ICG. The retention time of YQ-04-03 in tumors was significantly longer compared to other nonspecific uptake sites in the subjects, and its tumor-to-normal tissue ratio (TNR) outperformed ICG. Successful resection of in situ hepatocarcinoma and peritoneal carcinoma was achieved using probe imaging guidance, with the smallest visual lesion resected measuring approximately 1 mm3. Ultimately, this probe holds great potential for advancing tumor tracer.


Carcinoma, Hepatocellular , Liver Neoplasms , Surgery, Computer-Assisted , Humans , Fluorescent Dyes , Optical Imaging/methods , Surgery, Computer-Assisted/methods
8.
Int J Oral Maxillofac Implants ; 39(2): 263-270, 2024 Apr 24.
Article En | MEDLINE | ID: mdl-38657218

PURPOSE: To describe the use of digital technology to surgically guide the shell technique using allogenic cortical plates for a fully guided bone augmentation procedure. MATERIALS AND METHODS: A total of 10 patients who required bone augmentation for implant placement were included in this study. Allogenic cortical plates were planned using CAD/CAM to have identical thickness to the original cortical plates, then were digitally positioned and shaped to outline the bone defect according to the existing anatomical details. A cutting pattern and a surgical template were manufactured according to the digitally preplanned bone graft and the intraoral setting. RESULTS: A total of 12 horizontal bone grafting procedures were performed using the shell technique with allogenic cortical plates. All grafting procedures were deemed successful and allowed for ideal 3D implant positioning. Of the 12 bone grafting procedures, which used a surgical template to position the cortical plate, 3 required an adjustment to reposition the plate to a more ideal position. CONCLUSIONS: Digital technology was used to create a surgical template to guide the shell bone grafting technique with allogenic cortical plates. All surgical templates offered a fixed support to hold the cortical allogenic plate in the preplanned position, offering a predictable, simplified, and accurate guided bone grafting procedure. Further studies on a larger population of patients are necessary to assess those results and to verify the treatment approach described in this study.


Alveolar Ridge Augmentation , Bone Plates , Bone Transplantation , Computer-Aided Design , Humans , Prospective Studies , Male , Female , Alveolar Ridge Augmentation/methods , Middle Aged , Bone Transplantation/methods , Adult , Dental Implantation, Endosseous/methods , Treatment Outcome , Surgery, Computer-Assisted/methods , Transplantation, Homologous , Aged , Cone-Beam Computed Tomography
9.
Sci Rep ; 14(1): 8332, 2024 04 09.
Article En | MEDLINE | ID: mdl-38594498

Augmented reality (AR) has been used for navigation during total hip arthroplasty (THA). AR computed tomography (CT)-based navigation systems and AR-based portable navigation systems that use smartphones can also be used. This study compared the accuracy of cup insertion during THA using AR-CT-based and portable AR-based navigation systems. Patients with symptomatic hip disease who underwent primary THA in the supine position using both AR CT-based and portable AR-based navigation systems simultaneously between October 2021 and July 2023 were included. The primary outcome of this study was the absolute difference between cup angles in the intraoperative navigation record and those measured on postoperative CT. The secondary outcome was to determine the factors affecting the absolute value of the navigation error in radiographic inclination (RI) and radiographic anteversion (RA) of the cup, including sex, age, body mass index, left or right side, approach, and preoperative pelvic tilt. This study included 94 consecutive patients. There were 11 men and 83 women, with a mean age of 68 years. The mean absolute errors of RI were 2.7° ± 2.0° in the AR CT-based and 3.3° ± 2.4° in the portable AR-based navigation system. The mean absolute errors of RA were 2.5° ± 2.1° in the AR CT-based navigation system and 2.3° ± 2.2° in the portable AR-based navigation system. No significant differences were observed in RI or RA of the cup between the two navigation systems (RI: p = 0.706; RA: p = 0.329). No significant factors affected the absolute value of the navigation errors in RI and RA. In conclusion, there were no differences in the accuracy of cup insertion between the AR CT-based and portable AR-based navigation systems.


Arthroplasty, Replacement, Hip , Augmented Reality , Hip Prosthesis , Surgery, Computer-Assisted , Male , Humans , Female , Aged , Arthroplasty, Replacement, Hip/methods , Tomography, X-Ray Computed , Surgery, Computer-Assisted/methods , Acetabulum/surgery
10.
J Robot Surg ; 18(1): 160, 2024 Apr 05.
Article En | MEDLINE | ID: mdl-38578350

Robotic assisted (RA) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting novel platforms challenging. Therefore, we conducted a systematic review to assess the learning curve associated with RA-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). PubMed, MEDLINE, EBSCOhost, and Google Scholar were searched on June 16, 2023, to identify studies published between January 1, 2000 and June 16, 2023 (PROSPERO registration: CRD42023437339). The query yielded 655 unique articles, which were screened for eligibility. The final analysis included 11 articles, evaluating 1351 THA procedures. Risk of bias was assessed via the Methodological Index for Nonrandomized Studies (MINORS) tool. The mean MINORS score was 21.3 ± 0.9. RA-THA provided immediate improvements in acetabular component placement accuracy and radiographic outcomes compared to M-THA, with little to no experience required to achieve peak proficiency. A modest learning curve (12-17 cases) was associated with operative time, which was elevated compared to M-THA (+ 9-13 min). RA-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes. Surgeons should expect to experience increased operative times, which become less pronounced or equivalent to M-THA after a modest caseload.


Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Surgery, Computer-Assisted , Humans , Arthroplasty, Replacement, Hip/methods , Learning Curve , Robotic Surgical Procedures/methods , Acetabulum/diagnostic imaging , Acetabulum/surgery , Surgery, Computer-Assisted/methods
11.
BMC Oral Health ; 24(1): 415, 2024 Apr 05.
Article En | MEDLINE | ID: mdl-38575886

BACKGROUND: The objective of the present study was to evaluate the reliability of an augmented reality drilling approach and a freehand drilling technique for the autotransplantation of single-rooted teeth. MATERIALS AND METHODS: Forty samples were assigned to the following surgical techniques for drilling guidance of the artificial sockets: A. augmented reality technique (AR) (n = 20) and B. conventional free-hand technique (FT) (n = 20). Then, two models with 10 teeth each were submitted to a preoperative cone-beam computed tomography (CBCT) scan and a digital impression by a 3D intraoral scan. Afterwards, the autotrasplanted teeth were planned in a 3D dental implant planning software and transferred to the augmented reality device. Then, a postoperative CBCT scan was performed. Data sets from postoperative CBCT scans were aligned to the planning in the 3D implant planning software to analize the coronal, apical and angular deviations. Student's t-test and Mann-Whitney non-parametric statistical analysis were used to analyze the results. RESULTS: No statistically significant differences were shown at coronal (p = 0.123) and angular (p = 0.340) level; however, apical deviations between AR and FT study groups (p = 0.008) were statistically significant different. CONCLUSION: The augmented reality appliance provides higher accuracy in the positioning of single-root autotransplanted teeth compared to the conventional free-hand technique.


Augmented Reality , Dental Implants , Surgery, Computer-Assisted , Humans , Transplantation, Autologous , Reproducibility of Results , Computer-Aided Design , Cone-Beam Computed Tomography/methods , Imaging, Three-Dimensional
12.
BMJ Open Ophthalmol ; 9(1)2024 Apr 04.
Article En | MEDLINE | ID: mdl-38575345

OBJECTIVE: Preclinical validation study to assess the feasibility and accuracy of electromagnetic image-guided systems (EM-IGS) in orbital surgery using high-fidelity physical orbital anatomy simulators. METHODS: EM-IGS platform, clinical software, navigation instruments and reference system (StealthStation S8, Medtronic) were evaluated in a mock operating theatre at the Royal Victoria Eye and Ear Hospital, a tertiary academic hospital in Dublin, Ireland. Five high-resolution 3D-printed model skulls were created using CT scans of five anonymised patients with an orbital tumour that previously had a successful orbital biopsy or excision. The ability of ophthalmic surgeons to achieve satisfactory system registration in each model was assessed. Subsequently, navigational accuracy was recorded using defined anatomical landmarks as ground truth. Qualitative feedback on the system was also attained. RESULTS: Three independent surgeons participated in the study, one junior trainee, one fellow and one consultant. Across models, more senior participants were able to achieve a smaller system-generated registration error in a fewer number of attempts. When assessing navigational accuracy, submillimetre accuracy was achieved for the majority of points (16 landmarks per model, per participant). Qualitative surgeon feedback suggested acceptability of the technology, although interference from mobile phones near the operative field was noted. CONCLUSION: This study suggests the feasibility and accuracy of EM-IGS in a preclinical validation study for orbital surgery using patient specific 3D-printed skulls. This preclinical study provides the foundation for clinical studies to explore the safety and effectiveness of this technology.


Surgery, Computer-Assisted , Humans , Orbit/diagnostic imaging , Tomography, X-Ray Computed , Software , Electromagnetic Phenomena
13.
Adv Tech Stand Neurosurg ; 50: 295-305, 2024.
Article En | MEDLINE | ID: mdl-38592535

Surgical approaches directed toward craniovertebral junction (CVJ) can be addressed to the ventral, dorsal, and lateral aspects through a variety of 360° surgical corridors Herein, we report features, advantages, and limits of the updated technical support in CVJ surgery in clinical setting and dissection laboratories enriched by our preliminary surgical results of the simultaneous application of O-arm intraoperative neuronavigation and imaging system along with the 3D-4K EX in TOA for the treatment of CVJ pathologies.In the past 4 years, eight patients harboring CVJ compressive pathologies underwent one-step combined anterior neurosurgical decompression and posterior instrumentation and fusion technique with the aid of exoscope and O-arm. In our equipped Cranio-Vertebral Junction Laboratory, we use fresh cadavers (and injected "head and neck" specimens) whose policy, protocols, and logistics have already been elucidated in previous works. Five fresh-frozen adult specimens were dissected adopting an FLA. In these specimens, a TOA was also performed, as well as a neuronavigation-assisted comparison between transoral and transnasal explorable distances.A complete decompression along with stable instrumentation and fusion of the CVJ was accomplished in all the cases at the maximum follow-up (mean: 25.3 months). In two cases, the O-arm navigation allowed the identification of residual compression that was not clearly visible using the microscope alone. In four cases, it was not possible to navigate C1 lateral masses and C2 isthmi due to the angled projection unfitting with the neuronavigation optical system, so misleading the surgeon and strongly suggesting changing surgical strategy intraoperatively. In another case (case 4), it was possible to navigate and perform both C1 lateral masses and C2 isthmi screwing, but the screw placement was suboptimal at the immediate postoperative radiological assessment. In this case, the hardware displacement occurred 2 months later requiring reoperation.


Imaging, Three-Dimensional , Surgery, Computer-Assisted , Adult , Humans , Tomography, X-Ray Computed , Bone Screws , Cadaver
14.
J Cancer Res Ther ; 20(2): 651-657, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38687936

BACKGROUND: The feasibility and safety of enhanced recovery after surgery (ERAS) for percutaneous computed tomography (CT)-guided microwave ablation (MWA) for treating lung nodules remain unclear. METHODS AND MATERIALS: A total of 409 patients with lung tumors treated at the Department of Thoracic Surgery, First Affiliated Hospital of Guangxi Medical University from August 2020 to May 2023 were enrolled. Perioperative data, including baseline characteristics, operation time, postoperative pain score (visual analog scale [VAS]), hospitalization expenses, postoperative complications, total hospital stay, and patient satisfaction, were observed and recorded. RESULTS: No perioperative mortality occurred in either group and complete ablation was achieved in all patients. Patients in the ERAS group had significantly shorter hospital stays (P < 0.001), reduced operation times (P = 0.047), lower hospitalization expenses (P < 0.001), lower VAS scores (P < 0.001), and fewer complications (P = 0.047) compared with the traditional group. CONCLUSIONS: ERAS for percutaneous CT-guided MWA (ERAA) is safe, effective, and feasible for the treatment of lung nodules.


Enhanced Recovery After Surgery , Lung Neoplasms , Microwaves , Tomography, X-Ray Computed , Humans , Male , Lung Neoplasms/surgery , Lung Neoplasms/pathology , Female , Microwaves/therapeutic use , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed/methods , Aged , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Length of Stay/statistics & numerical data , Surgery, Computer-Assisted/methods , Treatment Outcome , Radiofrequency Ablation/methods , Radiofrequency Ablation/adverse effects , Adult , Feasibility Studies , Operative Time
16.
Surg Innov ; 31(3): 291-306, 2024 Jun.
Article En | MEDLINE | ID: mdl-38619039

OBJECTIVE: To propose a transfer learning based method of tumor segmentation in intraoperative fluorescence images, which will assist surgeons to efficiently and accurately identify the boundary of tumors of interest. METHODS: We employed transfer learning and deep convolutional neural networks (DCNNs) for tumor segmentation. Specifically, we first pre-trained four networks on the ImageNet dataset to extract low-level features. Subsequently, we fine-tuned these networks on two fluorescence image datasets (ABFM and DTHP) separately to enhance the segmentation performance of fluorescence images. Finally, we tested the trained models on the DTHL dataset. The performance of this approach was compared and evaluated against DCNNs trained end-to-end and the traditional level-set method. RESULTS: The transfer learning-based UNet++ model achieved high segmentation accuracies of 82.17% on the ABFM dataset, 95.61% on the DTHP dataset, and 85.49% on the DTHL test set. For the DTHP dataset, the pre-trained Deeplab v3 + network performed exceptionally well, with a segmentation accuracy of 96.48%. Furthermore, all models achieved segmentation accuracies of over 90% when dealing with the DTHP dataset. CONCLUSION: To the best of our knowledge, this study explores tumor segmentation on intraoperative fluorescent images for the first time. The results show that compared to traditional methods, deep learning has significant advantages in improving segmentation performance. Transfer learning enables deep learning models to perform better on small-sample fluorescence image data compared to end-to-end training. This discovery provides strong support for surgeons to obtain more reliable and accurate image segmentation results during surgery.


Neural Networks, Computer , Optical Imaging , Humans , Optical Imaging/methods , Neoplasms/surgery , Neoplasms/diagnostic imaging , Deep Learning , Image Processing, Computer-Assisted/methods , Surgery, Computer-Assisted/methods
17.
Neurol Res ; 46(5): 426-436, 2024 May.
Article En | MEDLINE | ID: mdl-38557428

OBJECTIVE: Pedicle screw stabilization (PSS) surgeries for spinal instability are still the most effective treatment approach. The use of preoperative planning can minimize the complications related to transpedicular screw (TPS) misplacement. The study aimed to evaluate the surgical outcomes of a guide device developed to improve the accuracy of the free-hand technique using three-dimensional planning in PSS. PATIENTS AND METHODS: Patients with degenerative spinal diseases who underwent open PSS between 2019 and 2022 were evaluated retrospectively. FG group included patients who were operated on using the fluoroscopy alone with preoperative two-dimensional planning. AFG group included patients who were operated on using a guide advice-assisted technique with preoperative 3DP. Between-group comparisons were performed. RESULTS: A total of 143 patients with a mean age of 59.6 years were included in the study. 71 patients were assessed in the FG group and 72 patients in the AFG group. Between-group comparisons regarding demographics, etiologies, radiation exposure, and functional improvements showed no significant differences (p > 0.05). Although the accuracy of TPSs positioning was 94.2% and 96.5% in the 2DG and 3DG, the difference between the groups was not statistically significant. The statistically significant differences regarding the upper-level facet joint violation and pedicle breach rates were lower in the AFG group (p < 0.0001; X2 = 19.57) and (p < 0.0001; X2 = 25.3), respectively. CONCLUSION: Using a guide device associated with preoperative 3PD reduced the upper-level facet joint violation and pedicle breach rates in open PSS surgeries performed by free-hand technique for degenerative spinal diseases.


Lumbar Vertebrae , Pedicle Screws , Humans , Middle Aged , Male , Female , Retrospective Studies , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Aged , Imaging, Three-Dimensional/methods , Preoperative Care/methods , Preoperative Care/instrumentation , Adult , Spinal Fusion/methods , Spinal Fusion/instrumentation , Treatment Outcome , Surgery, Computer-Assisted/methods , Surgery, Computer-Assisted/instrumentation , Fluoroscopy/methods
19.
Orthop Surg ; 16(5): 1143-1152, 2024 May.
Article En | MEDLINE | ID: mdl-38561920

OBJECTIVE: Medial opening-wedge high tibial osteotomy (MOWHTO) is a surgical procedure to treat medial compartment osteoarthritis in the knee with varus deformity. However, factors such as patellar height (PH) and the sagittal plane's posterior tibial slope angle (PTSA) are potentially overlooked. This study investigated the impact of alignment correction angle guided by computer-designed personalized surgical guide plate (PSGP) in MOWHTO on PH and PTSA, offering insights for enhancing surgical techniques. METHODS: This retrospective study included patients who underwent 3D-printed PSGP-assisted MOWHTO at our institution from March to September 2022. The paired t-tests assessed differences in all preoperative and postoperative measurement parameters. Multivariate linear regression analysis examined correlations between PTSA, CDI (Caton-Deschamps Index), and the alignment correction magnitude. Receiver operating characteristic (ROC) curve analysis determined the threshold of the correction angle, calculating sensitivity, specificity, and area under the curve. RESULTS: A total of 107 patients were included in our study. The CDI changed from a preoperative mean of 0.97 ± 0.13 (range 0.70-1.34) to a postoperative mean of 0.82 ± 0.13 (range 0.55-1.20). PTSA changed from a preoperative mean of 8.54 ± 2.67 (range 2.19-17.55) to a postoperative mean of 10.54 ± 3.05 (range 4.48-18.05). The t-test revealed statistically significant changes in both values (p < 0.05). A significant alteration in patellar height occurred when the correction angle exceeded 9.39°. Moreover, this paper illustrates a negative correlation between CDI change and the correction angle and preoperative PTSA. Holding other factors constant, each 1-degree increase in the correction angle led to a 0.017 decrease in postoperative CDI, and each 1-degree increase in preoperative PTSA resulted in a 0.008 decrease in postoperative CDI. PTSA change was positively correlated only with the correction angle; for each 1-degree increase in the opening angle, postoperative PTS increased by 0.188, with other factors constant. CONCLUSION: This study highlights the effectiveness and precision of PSGP-assisted MOWHTO, focusing on the impact of alignment correction on PH and PTSA. These findings support the optimization of PSGP technology, which offers simpler, faster, and safer surgeries with less radiation and bleeding than traditional methods. However, PSGP's one-time use design and the learning curve required for its application are limitations, suggesting areas for further research.


Osteoarthritis, Knee , Osteotomy , Patella , Surgery, Computer-Assisted , Tibia , Humans , Retrospective Studies , Osteotomy/methods , Female , Male , Middle Aged , Tibia/surgery , Patella/surgery , Adult , Osteoarthritis, Knee/surgery , Surgery, Computer-Assisted/methods , Aged , Printing, Three-Dimensional
20.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 43(2): 91-99, Mar-Abr. 2024. tab, graf, ilus
Article Es | IBECS | ID: ibc-231818

IntroducciónAnte el aumento constante de la demanda asistencial de exploraciones relacionadas con cirugía radioguiada (CRG), nuestro hospital adoptó incluir en el equipo de CRG nuevos perfiles profesionales con el fin de reducir parcialmente el tiempo de dedicación de los médicos nucleares a esta tarea.Objetivos: Analizar el proceso de incorporación de los perfiles de Técnico Superior en Imagen para el Diagnóstico (TSID) y Enfermera Referente de Ganglio Centinela (ERGC), evaluando su despliegue en los procedimientos ligados a la técnica. Material y métodos: Análisis de la actividad de CRG durante el periodo 2018-2022, centrándolo en los procedimientos prequirúrgicos y quirúrgicos relativos a cáncer de mama (CaM) y melanoma maligno (MM), por ser aquellas patologías en las que se concentró la transferencia de competencias asistenciales. Evolución cronológica de las competencias asumidas por los diferentes perfiles durante su integración en el equipo de CRG. Resultados: La actividad asistencial de CRG durante el periodo analizado experimentó un incremento del 109%. CaM y MM son las patologías que aglutinaron con diferencia una mayor demanda asistencial. La transferencia de competencias en estas dos patologías se ha producido de manera progresiva, asumiendo en 2022 el 74% (460/622) de la fase de administración el ERGC y el 64% (333/519) de las cirugías el TSID. Conclusiones: La creación de un equipo multidisciplinar de CRG, que incluye distintos perfiles profesionales (MN, ERGC y TSID), es una eficaz estrategia para dar respuesta al incremento de la complejidad y número de todos los procedimientos relacionados con la CRG.(AU)


Introduction: Given the constant increase in the healthcare demand for examinations related to radio-guided surgery (RGS), our hospital adopted new professional profiles in the RGS team, in order to partially reduce the time spent by nuclear medicine physicians on this task. Aim: To analyze the process of incorporating the profiles of Superior Diagnostic Imaging Technician (TSID) and Sentinel Node Referent Nurse (ERGC), evaluating their deployment in the procedures linked to the technique. Material and methods: Analysis of RGS activity during the period 2018-2022, focusing on pre-surgical and surgical procedures related to breast cancer (BC) and malignant melanoma (MM), as they are those pathologies on which the transfer of care competencies was concentrated. Chronological evolution of the competencies assumed by the different profiles during their integration into the RGS team. Results: RGS's healthcare activity during the analyzed period experienced an increase of 109%. BC and MM were the pathologies that accounted for by far the greatest demand for care. The transfer of competencies in these two pathologies occurred in a progressive and staggered manner, with 74% (460/622) of the administration phase being carried out by the ERGC and 64% (333/519) of the surgeries by the TSID in 2022. Conclusions: The creation of a multidisciplinary RGS team that includes different professional profiles (NM, ERGC and TSID) is an effective strategy to respond to the increase in the complexity and number of all procedures related to RGS.(AU)


Humans , Male , Female , Lymphoscintigraphy , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node Biopsy , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Surgery, Computer-Assisted , Nuclear Medicine , Molecular Imaging , Retrospective Studies
...